Oil & Gas - Upstream

Oil & Gas Upstream

"Oil & Gas are amongst the world's most important energy suppliers. Although new deposits are still being discovered, the conveyance of these raw materials is becoming more and more costly and requires constant technological development. Many of these reserves can be efficiently extracted and used by using NETZSCH progressing cavity pump systems. This requires very close cooperation with the oil and gas company experts right from the development stage of the new deposit, along with continuous improvement of pumps, drives and systems by our engineers and technicians. Difficult geological conditions, off-shore extraction and installation depths of more than 2,500 m are constantly setting new challenges for us in this area. By establishing NETZSCH Pump Centres in the most important extraction regions, we create an outstanding service environment for our partners all over the world. At the same time, NETZSCH products are moving into new application areas, such as dewatering gas boreholes and shallow geothermal energy."

Success Stories

NETZSCH Upstream conveys extremely difficult media to oil and gas fields

Despite all efforts to promote renewable energies, global demand for crude oil and natural gas has continued unabated. Methane from coal seams and highly viscous oil at more than 10,000 mPas are already of commercial interest, but are just as complicated to extract. In the Qinshui Basin in China the extraction is as difficult as the extraction of oil sand mixtures from the Sudanese desert where temperatures up to 50°C can be reached. More


Pumps for the Oil Industry

NETZSCH pumps for the oil industry are characterized by robust and reliable design. Constructions and materials are adapted to the requirements. Together with the customer's requirements are specified in the planning phase and the optimal pump is selected. The use of innovative pump technologies from NETZSCH offers safe and reliable production processes at low life-cycle costs. On this there is a large range of products available from which you can select the appropriate each pump system for on- and offshore, up-, mid- and downstream area.

Optimum UPSTREAM Solutions for Oil Water and Gas Production

Within the Business Unit Pumps & Systems the Business Field Oil & Gas Upstream specializes in the delivery of systems with progressing cavity pumps for the production of crude oil and other highly viscous materials; the pumps above mentioned are used throughout the world. Whether it is a large oilfield operator or a small production company – the experts at NETZSCH give their attention to all projects. At the same time we try to correspond to the increasing technological demands by highly efficient development work. Success in corporate research and development work with universities and operators of our pumps in the field confirms this fact.

NETZSCH Progressing Cavity Pumps for Upstream:

  • Standard Progressing Cavity Pumps
  • Insertable Progressing Cavity Pumps
  • NETZSCH Submersible Progressing Cavity Pumps

Application Range

Standard PCP

NTZ Progressing Cavity Pumps

  • Efficient handling of fluid High viscosity oil – more than 50.000 cP at the well head
  • High sand content – up to 40% at the suction side
  • High gas content – app. 40% free gas at the suction side
  • Water cut – up to 100%
  • Density – up to 0.82 kg/dm³ (45° API)
  • Temperature – up to max. 160°C
  • Pressure – up to 300 bar
  • Production – up to 300 m³/day (1900 bpd)

 

Key Advantages

  • Lower life cycle cost
  • Easy installation and transport
  • Less number of wear parts

 

NTZ-DT Geometry                       NTZ-ST Geometry

 

Your device is too small to show this table.
Pump Typenominal
production
rate [m³/d]
nominal
production
rate [bpd]
max.
differential
pressure
[bar]
minimum
tubing size
minimum
casing size
NTZ 166* 0,5 to 4,5    3 to 30      240     1,66"     3 1/2"
NTZ 238* 1,3 to 15    8 to 80      240     2 3/8"     3 1/2"
NTZ 278*    3 to 130  20 to 800      300     2 3/8"     4 1/2"
NTZ 350*  13 to 140  80 to 880      300     2 7/8"     5 1/2"
NTZ 400*  25 to 475160 to 3000      240     2 7/8"     5 1/2"
NTZ 450*  60 to 390375 to 2450      240     3 1/2"     6 5/8"
NTZ 500*110 to 475695 to 3000      200     4 1/2"     6 5/8"

Special Pumps & Systems

NETZSCH Insertable Progressing Cavity Pumps

The main feature of Progressing Cavity Pumps (rotor & stator) is their assembly inside the tubing. Thus, the pump is not connected to the production line but assembled inside it.

Applications

  • Wells with low flow – the cost of the intervention makes the use of a normal pump economically not suitable
  • Wells with a high frequency of interventions (independent of the flow)
  • Flow range 1,3 to 491 bpd at 100 rpm
  • Pressure range 100 to 240 bar
  • Pump with downhole sensors


Advantages

  • Minimization of the time of intervention
  • Minimization of costs of rig
  • Minimize rig’s costs in workover services, this minimizes production losses
  • Pump substitution without removing it from the tubing
  • Pump substitution with flushby equipment
  • Up to 60 % savings in pump replacement
  • Does not require removal of downhole sensors and cable

 

More detailed information please contact info.nps@netzsch.com.

NTU Progressing Cavity Pumps

Produced with steel tube conform with the same internal geometry as the stator (helical). Thus the elastomer has a uniform wall and produces even distribution of the elastomer. The main NTU pump feature is its lower operation and starting torque due to its lower swelling when exposed to temperature variations and chemically aggressive fluids.

Advantages

  • Short pump length
  • Lower starting and operational torque
  • Longer run life under severe fluid conditions
  • Less influence due to temperature and chemicals
  • Easier to assemble in wells with deviations
  • Lower hysteresis
  • Better heat dissipation

 

 

NTM Progressing Cavity Pump

  • Maximum flexibility in the  perspective of viscosity andtemperature
  • No chemical attack on the elastomer
  • Perfectly suited in combination with thermal treatment of the wells

Advantages

  • Short pump length
  • Lower starting and operational torque
  • Longer run life under severe fluid conditions
  • Less influence due to temperature and chemicals
  • Easier to assemble in wells with deviations
  • Lower hysteresis
  • Better heat dissipation

Submersible PCP

NETZSCH Submersible Progressing Cavity Pump

Advantages of the NETZSCH ESPCP

  • Designed for directional and horizontal wells
  • High efficiency – also with small production rates
  • No rod and no tubing wear
  • No gas lock associated with ESP
  • No environmental impact on the surface

 

Detailed Information: on request

Drive Heads & Equipment

NETZSCH Drive Head Types

General features

  • Different Polished Rod speed can be achieved by changing the pulleys or by using a Variable Speed Drive
  • All Drive Head Types can be supplied for the Polished Rod Sizes 1 1/4 and 1 1/2
  • Axial Load: 9 to 33 klb
  • Sealing system: Stuffing Box, Mechanical Seal or Lip Seal System
  • Flow Tee Connection: Flange API Spec. 6A Type 6B/Thread API 5B

NETZSCH Drive Heads – model ATEX – are approved in compliance with directive 94/9/EC for use in zone 1 (compared to name plate zone II 2G EEx c,k II T3 classification and the conformity declaration). The drive head is designed for commercial plant and in corformity to the following regulations and norms:

  • Conform to the Machinery Directive 2006/42/EC
  • Conform to the pertinent provisions of ATEX Directive 94/9/EC
  • Conform to the pertinent provisions of the following other directives
    - DIN EN 13463-1
    - DIN EN 13463-5
    - DIN EN 13463-8
  • DIN EN ISO 12100
  • DIN EN 1127-1
  • ISO 15136-2

Drive Head Accessories

Very often small accessories can be decisive for the safety of the service people and for the lifetime of the equipment. Therefore NETZSCH Pumpen & Systeme GmbH offers several special tools based on the service experience for more than
20 years PCP downhole pump installations and start

Benefits and special features

  • Use in explosives atmospheres (CE II 2G EEX c, k IIB T3)
  • Integrated overload protection
  • Integrated hydraulic brake
  • Integrated safety clamp
  • Exchangeable sealing box
  • Exchangeable flange connections

Spare parts sets are on request

Well Head Equipment

  • FBOP and SBOP
  • Flow Tee
  • Spool and Well Head Adapter

Rod String Equipment

  • Sucker Rod
  • Pony Rod and Polished Rod
  • Non Rotating Centralizer
  • Accessories