Food & Pharmaceuticals

 „In food processing, the production of cosmetics and the pharmaceutical industry in particular, we have to take special care with regard to the consumer. This of course means that all NEMO® and TORNADO® pumps are made according to the nationally and internationally relevant manufacturing and hygiene standards and guidelines.“

Rainer Gozzer

Business Field Manager Foods & Pharmaceuticals

 

Pumps for the Food and Pharmaceutical Industry

EHEDG, QHD, 3-A Sanitary Standard, materials specifications of the FDA – the list of hygiene guidelines for food conveyance systems is a long one. NETZSCH pumps meet all these requirements. Furthermore high-grade media can be conveyed in a clean and gentle manner through any stage of processing by NEMO® and TORNADO® Pumps. Our pumps open up new possibilities for your manufacturing processes. For media with high viscosity we offer NEMO® hopper pumps with conveying screws for gentle media handling.

Success Stories

Combination of macerator and specialised pump enables efficient collagen production

Fish is not just one of the staple foods in all the world's coastal regions, its high-quality constituents mean it is globally becoming a significant component of a healthy diet. Most of the residues are disposed of or processed into cheap animal feed, but the skins do for instance contain valuable proteins. One of the main global suppliers of catfish deals with customers in around 40 countries. The company does not just export the fish meat, but also produces high-quality by-products from the fish parts which would otherwise be designated as worthless residues. A key product is a collagen powder. More

Rotary lobe pump facilitates barrel emptying for a sauce manufacturer

When it comes to conveying systems in the foodstuff industry, the main focus is primarily on hygiene, cleanability and compatibility with food. When emptying containers using progressing cavity pumps for example, barrels can be drained to a residual quantity of less than one percent. And, thereby, they provide higher cleanliness and safety against contamination than, for example, open tilting devices. More

NEMO® progressing cavity pump reliably in application at a diary

A dairy in the US-State Wisconsin is specialized in liquid concentrated dairy blends. It is one of the largest manufacturer of frozen dairy mixes in the midwest and nationwide the largest producer of sweetened condensed milk. In addition, it manufactures a range of custom dairy blends that include acidified cloudifiers, alcohol cream liquor’s and other unique beverage formulations. More

Clean and smooth: special hygienic pump enables efficient yoghurt conveyance

Yoghurt is one of the exceptionally demanding conveyor media in the food sector. On the one hand, it is vital to avoid strong shear forces so as to protect the valuable bacteria cultures and prevent separation of the different phases. On the other hand, the product, like almost all dairy products, is critical in terms of hygiene, which means that all pump materials have to meet food safety requirements and comprehensive cleaning has to be carried out regularly. More    

Sweet, but abrasive: special food pump even conveys difficult baking mix hygienically and reliably

As popular as bakery products are, their production is often not without unforeseen difficulties, as for instance in a company making confectionery products in Southern Germany. More    

Special chocolate pump enables tempering across whole conveying area

Statistics tell us that every German citizen eats around 9.5 kg of chocolate a year, in the form of bars, hollow figures, pralines and such like. There is a particularly steep rise in consumption at Easter and Christmas.  Chocolate may be very popular, but it is extremely complicated to make. In particular, the temperature has to be precisely controlled at all times to achieve the later melt-in-your-mouth effect. More

Special oil-free rotary lobe pump reduces oil contamination risk in food production

Mineral oil hydrocarbons (MOH) are created during petroleum refining and are divided into two essential fractions: mineral oil saturated hydrocarbons (MOSH) and mineral oil aromatic hydrocarbons (MOAH). They do not only get into the products through packages. With chocolate, more...

Pennsylvania Brewing Company counts on Bavarian pump technology

In 1996 two friends with a passion for brewing premium beer opened the doors to the Brewing Company, a bar, restaurant and brewery in Downingtown, Pennsylvania. From a converted factory building where they brewed 1,725 barrels of beer in their first year. More

Pumping Sparkling Wine Without Foaming

Due to their sensitivity, wines are considered to be a difficult fluid to pump, while carbonated wines present completely different challenges: Each variety, for example, has a special carbon dioxide overpressure that must be observed. At the same time, the released CO2 increases the tendency of the beverage to foam, which impairs the quality of the goods. More...

Specialised conveying systems are increasing efficiency and hygiene in insulin production

Globally, there are around 285 million people who suffer from diabetes according to the estimates of the International Diabetes Federation (IDF) and this figure is predicted to be 438 million by 2030. More

Special hygienic rotary lobe pump delivers edible oil flexibly and with care

In everyday practice in the foodstuff industry high demands on hygienic processing are required for the primarily sensitive products, simultaneously, there is the high pressure of competition and efficiency. More

Gentle conveying characteristics of progressing cavity pumps
are optimal for mayonnaise production

NETZSCH's NEMO® hygienic pumps have proved to be very well suited to the requirements of mayonnaise production. The progressing cavity pumps work at low speeds and shear rates, which mean the product is protected from high forces. In addition, these pumps are designed for comprehensive CIP cleaning. More...

Self-priming, easy-to-clean barrel emptying system conveys juice with almost no residues

Juices and other drinks generally cause few problems when it comes to a company's internal material logistics - thanks to their good flow characteristics, they are easy to convey and empty out. However, such straightforward handling also leads to poor practices in terms of hygiene, such as when juice is openly decanted so that contaminants can enter the system. More

No reduction of quality during pasteurisation: Progressing cavity pumps gently convey chilli and tomato sauce

A food manufacturer used a multi screw pump to convey hot chilli and tomato sauce until 2015. However, this pump did not achieve the required flow rate and at the same time by shearing reduced the product quality. More...


Products

The new design of the TORNADO® rotary lobe pump T.Sano®

Smooth surface ensures easy cleaning

NEMO® Pump BY

NEMO® BY 모노펌프는 매우 다양한 물질들의 펌핑이 필요하거나 정밀하게 이송되어야 하는 산업의 어떤 분야에도 사용될 있습니다

NEMO® 식음료 펌프

NEMO® 식음료 펌프는 와인 재배, 생산, 양조장 및 각종 음료 생산 사업에 사용됩니다. 편리한 이동식 장치는 생산 환경에 필요한 유연성을 제공합니다.

NEMO® SY 모노펌프 - 베어링 블록 디자인/샤프트 연장

NEMO® SY 모노펌프는 세계의 모든 산업분야에서 요구하는 적용분야에 사용됩니다. 연장된 축과 베어링 하우징 구조로 이루어진 펌프는 서보 (Servo) 모터, 디젤 모터 혹은 유압모터와 같은 어떠한 타입의 드라이브와도 함께 운전할 있습니다.

NEMO® BO/BS 호퍼 모노펌프 (직경형 디자인 & 플랜지타입 모터)

NEMO® BO/BS 모노펌프는 정사각형/직사각형의 호퍼와 강제 이송 스크류 타입의 커플링 로드 강제이송 챔버를 구조를 하고 있으며, 대부분의 모든 산업분야에 적용되어 연속적이고 안정적인 압력 부드러운 저맥동의 이송을 제공합니다.

TORNADO® 로터리 로브 펌프 T2

TORNADO® 로타리 로브펌프는 용적식 펌프의 종류입니다. 펌핑 동작은 펌프 챔버 내에서 반대방향으로 회전하는 2개의 로터에 의해 발생합니다. 유체는 흡입구를 통해 펌프 챔버에 들어오며, 로터에 의해 챔버 주변를 따라 이동 , 토출구를 통해 이송됩니다.

NETZSCH Barrel Emptying Pumps

We’ll get the very last of it out for you!

NEMO® SA 무균 모노펌프

NEMO® SA 무균펌프는 식품, 제약, 화장품 화학/바이오화학 산업의 무균 위생 분야에 적용되어 연속적이고 안정적인 압력 부드러운 저맥동의 운전과 운전속도에 비례한 정량이송을 제공합니다.

NOTOS® Multi Screw Pump

The NOTOS® family has superior quality standards to meet the highest level requirements from our customers. The pumps are designed to work with low to high lubricant fluids, low to high viscosity, shear sensitive and/or chemically agressive media.

more information

NEMO® BH 위생형 펌프

NEMO® BH 위생형 펌프는 높은 위생성과 최적의 클렌징이 요구되는 식품, 제약, 화장품과 화학/바이오화학 산업분야에 적용됩니다. 운전속도에 비례한 정량이송 능력과 연속적이고 안정적인 압력 부드러운 저맥동의 이송 덕분에 모델은 이러한 적용에 이상적입니다.

NEMO® SH 플러스 위생 모노펌프

NEMO® SH Plus 위생펌프는 식품, 제약, 화장품 화학/바이오화학 산업의 위생 분야에 적용되어 연속적이고 안정적인 압력 부드러운 저맥동의 운전과 운전속도에 비례한 정량이송을 제공합니다.