NEMO® SH 플러스 위생 모노펌프

Your hygienic pump with a maintenance-free flexible rod!

일반사항

Universally applicable – the NEMO® SH Plus Hygienic Pump

The NEMO® SH Plus Hygienic Pump is employed for hygienic applications in the foodstuff, pharmaceutical, cosmetic and chemical/biochemical industries in order to provide continuous, pressure-stable, gentle and low-pulsation conveyance with optimal cleaning and dosing in proportion to speed.

The design with bearing block and free shaft ends enables the universal employment of any drive type.
Many different regulatory bodies have set specifications for a hygienically correct configuration of components and machines, as well as for component cleanability. NEMO PUMPS® are designed, produced and inspected in accordance with the regulations of the EHEDG (European Hygienic Equipment Design Group) and the QHD (Qualified Hygienic Design). The materials used are approved by the FDA (Food and Drug Administration) and the BfR (German Federal Institute for Risk Assessment). In addition, NEMO® Hygienic and Aseptic Eccentric Screw Pumps meet the specifications of the United States’ 3-A Sanitary Standards and are GOST-R certified (a Russian certificate of conformity).

Features of the NEMO® SH Plus Hygienic Pumps

  • continuous low-pulsation conveyance unaffected by fluctuations in pressure and viscosity
  • conveyance volume in proportion to rotation speed with high dosing precision over a broad rotational-speed range
  • high suction and pressure capability without valves
  • reversible conveyance direction
  • stator with hopper-shaped entrance for optimal filling of the conveying chamber

NEMO® SH Plus Hygienic Pumps offer you:

  • flexible rod design for uncompromising hygiene and long service life
  • gentle product conveyance
  • long production cycles with contamination-proof, sterile pump construction
  • CIP and SIP capability
  • product admission under vacuum conditions up to almost an absolute vacuum
  • open, patented hygienic joints for smearing media
  • elastomers approved for foodstuffs in accordance with FDA and BfR
  • horizontal and vertical installation
  • easy serviceability

Advantages of the NEMO® SH Plus Hygienic Pump:

  • foodstuff-suitable shaft seals with compression-proof bolted seal casing enable reversal of the direction of rotation and thereby also of the direction of conveyance, up to the maximum pump pressure
  • streamlined, crevice-free housing model prevents sedimentation of the product
  • all product-contacting surfaces are polished to prevent build-up of the medium and facilitate cleaning
  • the pump housing and stator can be optionally heated

Take advantage of our decades of experience and know-how in the manufacturing of positive-displacement pumps.

Your edge – process stability even under great demands!


기술사양

1 Rotor
In two geometries and with polished surfaces.

2 Stator with Reduced Walls
For changing temperatures, a patented stator with reduced elastomer wall thickness is used. In addition, a thermal stator protector (STP-2 or STP-D) provides protection against overheating and dry running. The stator inlet has a hopper-shaped opening for improved feed into the conveying chamber.

3 Drive Chain
The all-purpose flexible rod used for the transfer of power from the drive to the rotor in the NEMO® SH Plus Hygienic Pump is corrosion-resistant as well as dead-space, wear- and maintenance-free, because no components move against each other as they do in joints. Neither lubricants nor seals are needed, so the lubricative properties of the pumped product need not even be taken into account. This is ideal for sensitive substances with or without suspended solids and for uncompromising hygiene.

4 Seal Casing
Shaft seals suitable for contact with foodstuffs, with compression-proof, bolted shaft seal housing, enable a reversal of the direction of rotation up to the maximum pumping pressure.

5 Protective Tubing for Stator
Made of stainless steel (optional).

6 With Bearing Block and Free Shaft Ends
The design with bearing block and free shaft ends enables the universal employment of any drive type.

The NEMO® SH Plus Hygienic Pump is available …

  • in various sizes for flow rates up to 140 m3/h
  • for differential pressures up to 24 bar
  • with optional tangential CIP supports on the pump housing and end supports
  • with stators and gaskets with various elastomers approved for contact with foodstuffs.
  • with stators with reduced walls
  • with S & L Geometry for optimal adjustment to the application

… conveys…
sensitive substances under gentle, hygienic conditions

… and offers
a variety of shaft seals and construction types

Shaft Seals

single mechanical seal with elastomer bellows, with or without knife edges. Seal rings of SIC. Elastomer material also FDA-approved upon request.

Bi-directional, loaded

single mechanical seal with capsuled corrugated spring. Smooth outer contour. Seal rings of SIC. FDA-approved elastomer material.

Bi-directional, unloaded

Examples of optional components

Heating Rail and Heating Jacket
Optional heatable or coolable design of the pump housing and of the stator

CIP/SIP Process
To achieve the velocity of flow necessary for the cleaning fluid of at least 1.5 m/s in the entire system in accordance with CIP procedures, NEMO® Hygienic and Aseptic Pumps are equipped with additional flushing supports in tangential configuration and must be equipped with a bypass line. The bypass is also necessary for the SIP process. The NEMO® Pump operates in a synchronized fashion both for the CIP and for the SIP process. With tangential flushing supports, complete evacuation of the NEMO® pump is guaranteed. All pump materials are suitable for CIP and SIP processes.

Your edge – process stability even under great demands!

응용분야

Universally applicable – the NEMO® SH Plus Hygienic Pump

Your hygienic pump with a maintenance-free flexible rod!

The NEMO® SH Plus Hygienic Pump is employed for hygienic applications in the foodstuff, pharmaceutical, cosmetic and chemical/biochemical industries in order to provide continuous, pressure-stable, gentle and low-pulsation conveyance with optimal cleaning and dosing in proportion to speed. The flexible rod makes this pump ideal for sensitive substances – with or without suspended solids – when uncompromising hygiene is a must.

Wide Spectrum of Applications
The NEMO® SH Plus Hygienic Pump is used primarily for substances with the following properties:

  • shear-sensitive
  • low to very high viscosity
  • smearing or non-smearing
  • substances with or without solid content
  • thixotropic and dilatant
  • abrasive
  • adhesive

… such as
yeast, cream, mustard, mayonnaise, yogurt, soft cheeses, ointments, chunky sauces, eggs, milk, curd cheeses, honey, marmalade, syrup, ketchup, sourdough and many others.

Additional Features

  • high suction capability of up to 9 mWC
  • bi-directional
  • vertical or horizontal installation
  • low noise, low vibration

Large Range of Capacities and Pressures

  • adjustable capacities up to 140 m3/h
  • for differential pressures up to 24 bar

액세서리

The following accessories are available for the NEMO® SH Plus Hygienic Pump:

  • dry running protection units for NEMOLAST® stators
  • flow sensing unit for solid stators
  • speed monitoring device
  • diaphragm pressure gauges with various connections
  • multi-function pressure instrument
  • quench pot
  • pressurized flushing for double mechanical seal systems
  • chemical anchors
  • stator removal tool
  • adjustable feet
  • mobile and trailer mounted units
  • covers for drives

NEMO® BH 위생형 펌프

NEMO® BH 위생형 펌프는 높은 위생성과 최적의 클렌징이 요구되는 식품, 제약, 화장품과 화학/바이오화학 산업분야에 적용됩니다. 운전속도에 비례한 정량이송 능력과 연속적이고 안정적인 압력 부드러운 저맥동의 이송 덕분에 모델은 이러한 적용에 이상적입니다.

NEMO® SH 위생펌프

NEMO® SH 위생펌프는 식품, 제약, 화장품 및 화학/바이오화학 산업의 위생 분야에 적용되어 연속적이고 안정적인 압력 및 부드러운 저맥동의 운전과 운전속도에 비례한 정량이송을 제공합니다.

NEMO® SA 무균 모노펌프

NEMO® SA 무균펌프는 식품, 제약, 화장품 화학/바이오화학 산업의 무균 위생 분야에 적용되어 연속적이고 안정적인 압력 부드러운 저맥동의 운전과 운전속도에 비례한 정량이송을 제공합니다.


Literature