Oil & Gas - Mid-/Downstream

Vertical Sump Pump Provided for Oil Storage Application

When a major energy pipeline company looked to streamline their pumping system for their oil storage tanks, they called on NETZSCH to design and build customized vertical cavity sump pumps for lower maintenance and operational efficiencies.

 

Background

Along the customer’s pipeline are pumping stations needed to power the liquid fuels through the pipeline. At each pump station, there is a underground storage tank used as a collection point for excess oil from service work that is performed on main pipeline pumps. As the collection tanks fill to capacity, the customer needs to pump the liquid from the tank back into the pressurized pipeline.

 

Challenge

This process had consisted of a two-pump system – with a cantilever pump used to lift the excess oil out of the tank and a high-pressure piston plunger injection pump to move the oil back into the pipeline system.

 

Solution

NETZSCH progressive cavity pumps are tailor-made for this application, with dimensions to fit the customer’s existing underground tank. This pumps are also designed to operate in reverse, requiring the seal to be on the discharge side and the entire housing to be pressurized. The space-saving design of the entire pump disappears into the tank, providing for a very neat and clean installation. This also means that there is no additional effort needed to heat and isolate external equipment – a very important attribute in ambient operating temperatures down to -40°C. No concerns or issues from field operators. With the success of this installation, the customer has changed their current specification regarding these sump pumps to include or recommend the use of the NETZSCH pump for this application.

 

 


Questionaire

기술사양

당신의 모바일기기는 너무 작아서 이 테이블을 볼 수 없습니다.
NETZSCHVertical Progressing Cavity Sump Pump
MediumOil

Throughput volume
4.5 m³/h
Rotation speed232 rpm
Pressure50 bar
Viscosity100 cP
Temperature-5°C

제품 소개

NEMO® 이송용 펌프

보통 항구나 정제소는 꽤 먼 거리에 위치해 있습니다. 그러므로 가능한 가장 낮은 맥동에서 높은 운반 압력을 유지할 수 있는 펌프 시스템이 필요합니다. 

NEMO® C.Pro®

NEMO® N-Ipos CY C.Pro® 도징 펌프는 환경 화학산업에서 사용되는 다양한 화학물의 정량이송을 위한 온전한 합성소재 펌프입니다. 합성소재 구조는 부식성이 심하거나 심하지 않은 화학물을 부드러운 저맥동으로 이송하는 적합합니다.

 more information

NEMO® 다상유동 펌프

추출된 원유는 보통 물, 모래 및 가스와 혼합된 상태입니다. 기존 펌프는 원유에서의 가스 분리를 요하지만 네취NEMO® 다상유동 펌프는 가스 함유량이 최대 100%인 원유에서도 사용할 수 있습니다. 

NEMO® SY 모노펌프 - 베어링 블록 디자인/샤프트 연장

NEMO® SY 모노펌프는 세계의 모든 산업분야에서 요구하는 적용분야에 사용됩니다. 연장된 축과 베어링 하우징 구조로 이루어진 펌프는 서보 (Servo) 모터, 디젤 모터 혹은 유압모터와 같은 어떠한 타입의 드라이브와도 함께 운전할 있습니다.

NEMO® 워터-인젝션 펌프

원유는 종종 해면암에서 발견되며 이를 추출하기 위해서는 반드시 고 압력에서 펌핑되어야 합니다. NEMO® 워터-인젝션 펌프는 회전 속도에 따라 용량 변경이 가능하므로 이러한 작업에 적합합니다.

NEMO® Pump BY

NEMO® BY 모노펌프는 매우 다양한 물질들의 펌핑이 필요하거나 정밀하게 이송되어야 하는 산업의 어떤 분야에도 사용될 있습니다


문헌