Meats Industry

Rotary lobe pump facilitates barrel emptying for a sauce manufacturer

When it comes to conveying systems in the foodstuff industry, the main focus is primarily on hygiene, cleanability and compatibility with food.  

 

Look behind the scenes

When emptying containers using progressing cavity pumps for example, barrels can be drained to a residual quantity of less than one percent. And, thereby, they provide higher cleanliness and safety against contamination than, for example, open tilting devices.  

 

Challenge accepted

A sauce manufacturer had repeated problems when emptying the basic cooker using a raising-tilting system: Spraying, hot medium and the resulting slippery floor were also problematic with regard to hygiene and the occupational safety and material losses were also not to be underestimated.  

 

Excellently solved

As classical emptying of the container was not suitable due to the shape of the cooker and the kitchen provided too little space for a progressing cavity pump, for this case of application, NETZSCH recommended another displacement pump system, the T.Sano® rotary lobe pump. The T.Sano® full metal pump is connected to the basic cooker and the actual cooking vessel by hoses safe for food. The prepared base product can then be easily pumped into the next container for refining. Hazardous spray and slippery floors are a thing of the past, the hygiene standard can be significantly increased by the enclosed conveying system. Furthermore, time-consuming and staff-intensive manual movement of the goods is omitted. The ingredients of the sauce, are not impaired by this gentle conveying: The rotary lobe pump features a large free ball passage. Thus, displacement technology is a suitable, efficient solution for conveying for all types of requirement in the food sector.

기술사양

당신의 모바일기기는 너무 작아서 이 테이블을 볼 수 없습니다.
NETZSCHT.Sano® rotary lobe pump
MediumSauce cadre

제품 소개

NEMO® BF 모노펌프 (호퍼/이송 스크류)

NEMO® BF운전속도에 비례한 정량이송과 함께 맥동 안정적인 압력과 부드럽고 연속적인 운전을 제공하는 대부분의 모든 산업분야에 사용될 있습니다. 펌프는 브릿지를 형성하지 않는 고점도의 촘촘하고 부스러지기 쉬운 물질에 주로 적용됩니다.

NEMO® C.Pro®

NEMO® N-Ipos CY C.Pro® 도징 펌프는 환경 화학산업에서 사용되는 다양한 화학물의 정량이송을 위한 온전한 합성소재 펌프입니다. 합성소재 구조는 부식성이 심하거나 심하지 않은 화학물을 부드러운 저맥동으로 이송하는 적합합니다.

 more information

NEMO® Pump BY

NEMO® BY 모노펌프는 매우 다양한 물질들의 펌핑이 필요하거나 정밀하게 이송되어야 하는 산업의 어떤 분야에도 사용될 있습니다

NEMO® BH 위생형 펌프

NEMO® BH 위생형 펌프는 높은 위생성과 최적의 클렌징이 요구되는 식품, 제약, 화장품과 화학/바이오화학 산업분야에 적용됩니다. 운전속도에 비례한 정량이송 능력과 연속적이고 안정적인 압력 부드러운 저맥동의 이송 덕분에 모델은 이러한 적용에 이상적입니다.

NEMO® BO/BS 호퍼 모노펌프 (직경형 디자인 & 플랜지타입 모터)

NEMO® BO/BS 모노펌프는 정사각형/직사각형의 호퍼와 강제 이송 스크류 타입의 커플링 로드 강제이송 챔버를 구조를 하고 있으며, 대부분의 모든 산업분야에 적용되어 연속적이고 안정적인 압력 부드러운 저맥동의 이송을 제공합니다.


문헌