Oil & Gas Mid-/Downstream

"The effective use of our world’s oil and gas deposits represents one of the greatest challenges of our time. In particular, our NEMO®, NOTOS® and TORNADO® pump systems offer new opportunities to leverage dwindling oil resources and raise production rates of existing oil fields. Besides lower quality crude oils and high viscous oils also multiphase fluids can be produced economically and efficiently.“

Ulrich Eibl
Business Field Manager Oil & Gas Mid-/Downstream


Pumps for the Oil Industry

NETZSCH pumps for the oil industry are characterized by robust and reliable design. Constructions and materials are adapted to the requirements. Together with the customer's requirements are specified in the planning phase and the optimal pump is selected. The use of innovative pump technologies from NETZSCH offers safe and reliable production processes at low life-cycle costs. On this there is a large range of products available from which you can select the appropriate each pump system for on- and offshore, up-, mid- and downstream area.

Success Stories

Constant delivery rate regardless of the product viscosity:
NEMO® progressing cavity pumps in a remote oilfield

The transfer of crude oil always presents new challenges and so it was on an oilfield in the Tatarstan region of Russia. Crude oil, containing up to three percent sand, is conveyed there in a 24-hour operation...more

NOTOS® multi screw pumps proof their strength

When pumps are used on ships and in ports, the technology must meet special requirements: this means the pumps should not only cope with a really wide variety of fluids, but should also be as space-saving, maintenance-free and easy to handle as possible. More

Screw pumps strip out even highly viscous media

As containers and temporary storage, tanks to entire tank farms are the backbone of many industries, in particular in the oil and fuel sector. But these types of media are often highly viscous, making it difficult to empty or ‘strip’ all the medium out of the tanks. Residual product is normally left behind, significantly reducing the useful volume of the tank. More and more companies in these sectors are now using NOTOS® screw pumps from NETZSCH Pumpen & Systeme GmbH to maximise the profitability of their tanks. More...

Vertical Sump Pump Provided for Oil Storage Application

When a major energy pipeline company looked to streamline their pumping system for their oil storage tanks, they called on NETZSCH to design and build customized vertical cavity sump pumps for lower maintenance and operational efficiencies. More


NEMO® 워터-인젝션 펌프

원유는 종종 해면암에서 발견되며 이를 추출하기 위해서는 반드시 고 압력에서 펌핑되어야 합니다. NEMO® 워터-인젝션 펌프는 회전 속도에 따라 용량 변경이 가능하므로 이러한 작업에 적합합니다.

Dependable conveyance with no overflow

NEMO® Immersible 펌프는 베럴, 탱크 혹은 피트를 비우는 용도로 사용됩니다. 또한 장소가 제한되고 캐비테이션의 위험성이 있는 곳에 사용됩니다. 추가적으로 이러한 펌프들은 위험물에서 물과 환경물질을 담고 있는 베럴을 비우는 적합합니다.

NEMO® 이송용 펌프

보통 항구나 정제소는 꽤 먼 거리에 위치해 있습니다. 그러므로 가능한 가장 낮은 맥동에서 높은 운반 압력을 유지할 수 있는 펌프 시스템이 필요합니다. 

NEMO® SY 모노펌프 - 베어링 블록 디자인/샤프트 연장

NEMO® SY 모노펌프는 세계의 모든 산업분야에서 요구하는 적용분야에 사용됩니다. 연장된 축과 베어링 하우징 구조로 이루어진 펌프는 서보 (Servo) 모터, 디젤 모터 혹은 유압모터와 같은 어떠한 타입의 드라이브와도 함께 운전할 있습니다.

NEMO® 다상유동 펌프

추출된 원유는 보통 물, 모래 및 가스와 혼합된 상태입니다. 기존 펌프는 원유에서의 가스 분리를 요하지만 네취NEMO® 다상유동 펌프는 가스 함유량이 최대 100%인 원유에서도 사용할 수 있습니다. 


NEMO® BY 모노펌프는 매우 다양한 물질들의 펌핑이 필요하거나 정밀하게 이송되어야 하는 산업의 어떤 분야에도 사용될 있습니다

TORNADO® Rotary Lobe Pump – special design for the petroleum industry

NETZSCH TORNADO® Rotary Lobe Pumps are used in the petroleum industry for the continuous, pressure-stable, gentle and low-pulsation conveyance of crude oil. The TORNADO® is particularly well suited for running high capacities at medium pressures.